#906 closed баг (fixed)

Цветовая индикация в платах ST-124M/116M/018M не работает

Reported by: roman_zhur Owned by: alx
Priority: средний Milestone: 2 очередь
Component: web-интерфейс (sw) Keywords:
Cc:

Description (last modified by roman_zhur)

Ожидалось, что на платах ST-124M/116M/018M на вкладке Состояние при отсутствии аварий при включенном оптическом интерфейсе прямоугольник с названием аварии будет окрашен в зеленый (см. тикет #890).
Однако они серые.

Версия sw: 1.0-r2842

Attachments (2)

1.png​ (63.0 KB ) - added by roman_zhur 7 weeks ago.
1.mp4​ (228.8 KB ) - added by roman_zhur 7 weeks ago.

Download all attachments as: .zip

Change History (15)

by roman_zhur, 7 weeks ago

Attachment: 1.png​ added

comment:1 by alx, 7 weeks ago

Для диагностики прошу выполнить следующий запрос:

http://<host>/api.php?json={"cmd":"snmpget","varlits":[".4.<slot>.6.0"],"strings2data":true},

где "<host>" - адрес платы SW-01, "<slot>" - номер слота, в котором установлена плата ST-018M/ST-116M/ST-124M. Ответ платы покажи, пожалуйста, здесь.

comment:2 by roman_zhur, 7 weeks ago

Description: modified (diff)

забыл указать версию sw

comment:3 by roman_zhur, 7 weeks ago

ответ на запрос: {"cmd":"snmpget","error":"no 'varlist' field"}.

уточню баг: прямоугольник с названием аварии окрашивается в зеленый (при включении оптики, когда аварии нет) или серый (при выключении оптики) только после того, как закрыть и открыть диалоговое окно конфигурации платы.

in reply to:  3 comment:4 by alx, 7 weeks ago

Replying to roman_zhur:

ответ на запрос: {"cmd":"snmpget","error":"no 'varlist' field"}.

Прошу прощения, опечатался в названии поля. Правильный запрос такой:

http://<host>/api.php?json={"cmd":"snmpget","varlist":[".4.<slot>.6.0"],"strings2data":true}

уточню баг: прямоугольник с названием аварии окрашивается в зеленый (при включении оптики, когда аварии нет) или серый (при выключении оптики) только после того, как закрыть и открыть диалоговое окно конфигурации платы.

??? Я не понял твоего утонения... Прямоугольники, отображающие состояния аварий (давай для краткости называть их "индикаторы") находятся в диалоге конфигурации платы. Советшенно понятно, что видеть их ты можешь только тогда, когда диалог открыт. Если диалог закрыт (то есть его нет), то и никаких индикаторов нет...

comment:5 by roman_zhur, 7 weeks ago

ответ на запрос:

{"cmd":"snmpget","result":{".4.2.6.0":{"oid":".4.2.6.0","status":"OK","value":[53,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,1,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,3,0,49,0,0,0,0,0,0,0,0,0,0,0,0,0,0,50,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,32,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,2,2,0,0,0,0,0,1,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,3,0,50,0,0,0,0,0,0,0,0,0,0,0,0,0,0,48,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,32,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,2,2,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,1,44,44,0,15,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,15,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,15,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,15,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,15,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,15,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,15,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,15,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,2,0,191,1,0,0,0,0,191,1,0,0,0,0,191,1,0,0,0,0,191,1,0,0,0,0,3,0,22,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,54,54,54,54,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0]}}}
Last edited 7 weeks ago by roman_zhur (previous) (diff)

comment:6 by roman_zhur, 7 weeks ago

Я не понял твоего утонения...

  1. Открываю диалог конфигурации платы (в данном случае ST-018M)
  2. Включаю оптику A и B, настраиваю поля J0
  3. Нажимаю кнопку "Применить"
  4. Перехожу на вкладку "Состояние"
  5. Вижу, что горят только индикаторы, в которых есть авария. Остальные индикаторы серые
  6. Закрываю диалоговое окно конфигурации платы
  7. Открываю диалоговое окно конфигурации платы
  8. Перехожу на вкладку "Состояние"
  9. Индикаторы без аварий горят зеленым

  1. Выключаю оптику B
  2. Нажимаю кнопку "Применить"
  3. Перехожу на вкладку "Состояние"
  4. Индикаторы оптики B горят зеленым, хотя в п.3.1 указано, что "Направление B: выключено"
  5. Закрываю диалоговое окно конфигурации платы
  6. Открываю диалоговое окно конфигурации платы
  7. Перехожу на вкладку "Состояние"
  8. Индикаторы оптики B серые
Version 0, edited 7 weeks ago by roman_zhur (next)

by roman_zhur, 7 weeks ago

Attachment: 1.mp4​ added

in reply to:  5 comment:7 by alx, 7 weeks ago

Replying to roman_zhur:

ответ на запрос:

Спасибо. Судя по ответу, в этой плате включено направление A и выключено направление B. Соответственно, на вкладке "Состояние" в группе 2 индикаторы, не имеющие аварий, должны иметь зеленый фон, а в группе 3 - серый. А у тебя почему-то в обеих группах серый...

in reply to:  6 ; comment:8 by alx, 7 weeks ago

Replying to roman_zhur:

Я не понял твоего утонения...

  1. Открываю диалог конфигурации платы (в данном случае ST-018M)
  2. Включаю оптику A и B, настраиваю поля J0

О, интересное дополнение! Верно ли я, в таком случае, понял, что изначально (до выполнения пункта 1) направления STM A и STM B выключены?

in reply to:  8 comment:9 by roman_zhur, 7 weeks ago

О, интересное дополнение! Верно ли я, в таком случае, понял, что изначально (до выполнения пункта 1) направления STM A и STM B выключены?

Да. Изначально оба направления выключены

comment:10 by roman_zhur, 7 weeks ago

Поправил ответ на запрос в comment:5 - оба направления включены

in reply to:  6 comment:11 by alx, 7 weeks ago

Replying to roman_zhur:

  1. Открываю диалог конфигурации платы (в данном случае ST-018M)

....

  1. Индикаторы оптики B серые

Спасибо. Теперь, когда ты описал свои действия, я смог найти ошибку.

Напомню, что хороший баг-рипорт состоит из трех основных частей: что делали, что ожидали получить в результате, и что получили вместо ожидаемого. В описании тикета, к сожалению, отсутствовала первая часть, и это не позволило мне сразу понять, в чем проблема... :)

in reply to:  10 comment:12 by alx, 7 weeks ago

Replying to roman_zhur:

Поправил ответ на запрос в comment:5 - оба направления включены

Спасибо, это мне уже не требуется.

comment:13 by alx, 7 weeks ago

Resolution: → fixed
Status: new → closed

In 2844/sw:

Исправлена ошибка в веб-интерфейсе: в диалоге конфигурации
плат ST-018M, ST-116M, ST-124M после записи новой конфигурации
не обновлялся класс индикаторов аварий на вкладке "Состояние".
Причина была в том, что обновление было добавлено в метод
update_6(), а он выполняется только при загрузке конфига
из платы и сбросе в дефолт. Теперь обновление перемещено
в метод visualize().
Closes #906.