wiki:TicketQuery

TicketQuery Wiki Macro

The TicketQuery macro lets you display ticket information anywhere that accepts WikiFormatting. The query language used by the [[TicketQuery]] macro is described in the TracQuery page.

Usage

[[TicketQuery]]

Wiki macro listing tickets that match certain criteria.

This macro accepts a comma-separated list of keyed parameters, in the form "key=value".

If the key is the name of a field, the value must use the syntax of a filter specifier as defined in TracQuery#QueryLanguage. Note that this is not the same as the simplified URL syntax used for query: links starting with a ? character. Commas (,) can be included in field values by escaping them with a backslash (\).

Groups of field constraints to be OR-ed together can be separated by a literal or argument.

In addition to filters, several other named parameters can be used to control how the results are presented. All of them are optional.

The format parameter determines how the list of tickets is presented:

  • list -- the default presentation is to list the ticket ID next to the summary, with each ticket on a separate line.
  • compact -- the tickets are presented as a comma-separated list of ticket IDs.
  • count -- only the count of matching tickets is displayed
  • rawcount -- only the count of matching tickets is displayed, not even with a link to the corresponding query (since 1.1.1)
  • table -- a view similar to the custom query view (but without the controls)
  • progress -- a view similar to the milestone progress bars

The max parameter can be used to limit the number of tickets shown (defaults to 0, i.e. no maximum).

The order parameter sets the field used for ordering tickets (defaults to id).

The desc parameter indicates whether the order of the tickets should be reversed (defaults to false).

The group parameter sets the field used for grouping tickets (defaults to not being set).

The groupdesc parameter indicates whether the natural display order of the groups should be reversed (defaults to false).

The verbose parameter can be set to a true value in order to get the description for the listed tickets. For table format only. deprecated in favor of the rows parameter

The rows parameter can be used to specify which field(s) should be viewed as a row, e.g. rows=description|summary

The col parameter can be used to specify which fields should be viewed as columns. For table format only.

For compatibility with Trac 0.10, if there's a last positional parameter given to the macro, it will be used to specify the format. Also, using "&" as a field separator still works (except for order) but is deprecated.

Examples

Example Result Macro
Number of Triage tickets: 158 [[TicketQuery(status=new&milestone=,count)]]
Number of new tickets: 158 [[TicketQuery(status=new,count)]]
Number of reopened tickets: 7 [[TicketQuery(status=reopened,count)]]
Number of assigned tickets: 30 [[TicketQuery(status=assigned,count)]]
Number of invalid tickets: 47 [[TicketQuery(status=closed,resolution=invalid,count)]]
Number of worksforme tickets: 0 [[TicketQuery(status=closed,resolution=worksforme,count)]]
Number of duplicate tickets: 0 [[TicketQuery(status=closed,resolution=duplicate,count)]]
Number of wontfix tickets: 0 [[TicketQuery(status=closed,resolution=wontfix,count)]]
Number of fixed tickets: 78 [[TicketQuery(status=closed,resolution=fixed,count)]]
Number of untriaged tickets (milestone unset): 195 [[TicketQuery(status!=closed,milestone=,count)]]
Total number of tickets: 1443 [[TicketQuery(count)]]
Number of tickets reported or owned by current user: 0 [[TicketQuery(reporter=$USER,or,owner=$USER,count)]]
Number of tickets created this month: 1 [[TicketQuery(created=thismonth..,count)]]
Number of closed Firefox tickets: 0 [[TicketQuery(status=closed,keywords~=firefox,count)]]
Number of closed Opera tickets: 0 [[TicketQuery(status=closed,keywords~=opera,count)]]
Number of closed tickets affecting Firefox and Opera: 0 [[TicketQuery(status=closed,keywords~=firefox opera,count)]]
Number of closed tickets affecting Firefox or Opera: 0 [[TicketQuery(status=closed,keywords~=firefox|opera,count)]]
Number of tickets that affect Firefox or are closed and affect Opera: 0 [[TicketQuery(status=closed,keywords~=opera,or,keywords~=firefox,count)]]
Number of closed Firefox tickets that don't affect Opera: 0 [[TicketQuery(status=closed,keywords~=firefox -opera,count)]]
Last 3 modified tickets: #1443, #1428, #1423 [[TicketQuery(max=3,order=modified,desc=1,compact)]]

Details of ticket #1:

[[TicketQuery(id=1,col=id|owner|reporter,rows=summary,table)]]

Ticket Owner Reporter
#1 san san
Summary Добавить функцию "Отключение ДП с таймером"

Format: list

[[TicketQuery(version=0.6|0.7&resolution=duplicate)]]

This is displayed as:

No results

[[TicketQuery(id=123)]]

This is displayed as:

#123
Ошибка на странице сайта

Format: compact

[[TicketQuery(version=0.6|0.7&resolution=duplicate, compact)]]

This is displayed as:

No results

Format: count

[[TicketQuery(version=0.6|0.7&resolution=duplicate, count)]]

This is displayed as:

0

Format: progress

[[TicketQuery(milestone=0.12.8&group=type,format=progress)]]

This is displayed as:

дефект

554 / 664

улучшение

448 / 517

задача

246 / 262

Format: table

You can choose the columns displayed in the table format (format=table) using col=<field>. You can specify multiple fields and the order they are displayed by placing pipes (|) between the columns:

[[TicketQuery(max=3,status=closed,order=id,desc=1,format=table,col=resolution|summary|owner|reporter)]]

This is displayed as:

Results (1 - 3 of 1248)

1 2 3 4 5 6 7 8 9 10 11
Ticket Resolution Summary Owner Reporter
#1443 готово РЭ: исправить описание подключения к разъёму S платы PE-14 Vladimir san
#1441 готово РЭ: странное требование по заземлению Vladimir alx
#1440 готово РЭ: уточнить, какие типы соединительных кабелей являются другими Vladimir alx
1 2 3 4 5 6 7 8 9 10 11

Full rows

In table format you can specify full rows using rows=<field>:

[[TicketQuery(max=3,status=closed,order=id,desc=1,format=table,col=resolution|summary|owner|reporter,rows=description)]]

This is displayed as:

Results (1 - 3 of 1248)

1 2 3 4 5 6 7 8 9 10 11
Ticket Resolution Summary Owner Reporter
#1443 готово РЭ: исправить описание подключения к разъёму S платы PE-14 Vladimir san
Description

Разработчик платы PE-14 обнаружил в РЭ-79 в п 5.12.3 Подключение Ethernet и устройства сигнализации к плате РE текст, который может ввести в заблуждение пользователей:

Разъем S предназначен для подключения внешнего устройства сигнализации.
Если устройство сигнализации имеет собственный источник питания, то оно подключается
к контактам 2, 4 разъёма S. При этом на плате не должны быть установлены перемычки 12V и 0V.
При возникновении события контакты 1, 2 замыкаются через реле платы. Допустимый ток
через реле – 5 А при переменном напряжении 220 В и 1 А при постоянном напряжении до 60 В.
Если устройство сигнализации не имеет собственного источника питания, то оно
подключается к контактам 1, 3 разъёма S. При этом на плате должны быть установлены
перемычки 12V и 0V. Контакт 4 соединён с землёй, на контакт 2 при возникновении события через
реле подаётся постоянное напряжение +12 В. Допустимый ток через реле – 1 А.
Также через разъем S можно запитать внешнее устройство внутренним напряжением
блока +12V. При этом на плате должны быть установлены перемычки 12V и 0V.
Подключение к разъёму S следующее:
контакт 4: +12 Вольт,
контакт 3: 0 Вольт (земля).

Предлагаемый текст замены ниже. Ещё я предлагаю добавить рисунок, для объяснения подключения сигнализации от 220 В. Рисунок принесу на бумажке)


Разъем S предназначен для подключения внешнего устройства сигнализации.

Если устройство сигнализации работает от сети ~220В, то оно подключается к контакту 2 разъёма S. На контакт 4 разъёма S подается фаза сети 220В. Нейтраль 220В подключается к устройству сигнализации напрямую. При этом на плате ОБЯЗАТЕЛЬНО ДОЛЖНЫ БЫТЬ СНЯТЫ перемычки 12V и 0V. <рисунок> При возникновении события контакты 2 и 4 замыкаются через реле платы. Допустимый ток через реле – 5А.

Если устройство сигнализации не имеет собственного источника питания и работает от напряжения 12 В, то оно подключается к контактам 3 и 4 разъёма S. контакт 4: +12 В контакт 3: 0 В (земля) При этом на плате должны быть установлены перемычки 12V и 0V. Контакт 3 соединён с землёй блока, на контакт 4 при возникновении события через реле подаётся постоянное напряжение +12 В из блока MC04-DSL-3U. Допустимый ток через реле – 1 А.

Также через разъем S можно запитать внешнее устройство внутренним напряжением блока +12V. При этом на плате должны быть установлены перемычки 12V и 0V. Подключение к разъёму S следующее: контакт 4: +12 В контакт 3: 0 В (земля)

#1441 готово РЭ: странное требование по заземлению Vladimir alx
Description

В РЭ аппаратуры MC04-DSL-3U редакции 78 в разделе 9.2 на странице 440 я обнаружил такое требование:

Перед подключением к блоку измерительных приборов или компьютера, их необходимо

заземлить, используя клеммы защитного заземления на каркасе стойки или шкафа.

Это требование мне кажется странным и трудновыполнимым.

Во-первых, компьютер и измерительные приборы, подключающиеся к электрической розетке, уже и так заземляются через провод заземления в розетке. Непонятно, зачем заземлять их еще одним дополнительным соединением.

Во-вторых, и на компьютерах, и на большинстве виденных мной приборов (осциллографов, частотомеров) нет специальной отдельной клеммы заземления (так как, как я написал выше, они заземляются через электророзетку). Поэтому подключать дополнительное заземление к ним просто некуда, что делает процитированное требование трудновыполнимым... Наконец, бывают измерительные приборы, заземление которых не предусмотрено в принципе. Как, например, заземлить тестер с питанием от встроенной батарейки, у которого просто нет никаких доступных металлических частей?

Нет ли в процитированном требовании ошибки?

Предлагаю исключить процитированное требование из текста РЭ.

#1440 готово РЭ: уточнить, какие типы соединительных кабелей являются другими Vladimir alx
Description

В РЭ аппаратуры MC04-DSL-3U редакции 78 в разделе 9.3 на странице 441 есть такой абзац:

Другие типы соединительных кабелей и проводов могут вызвать отражение сигналов SHDSL от точки соединения с линейным кабелем на кабельном боксе, что снизит помехоустойчивость принимаемых сигналов в аппаратуре MC04−DSL.

Из написанного я не смог понять, какие именно типы соединительных кабелей и проводов являются другими. Предполагаю, что это не будет понятно и другим читателям.

Для внесения большей определенности предлагаю уточнить процитированную фразу, указав, какие именно типы соединительных кабелей и проводов могут вызвать отражение сигналов SHDSL от точки соединения с линейным кабелем на кабельном боксе.

1 2 3 4 5 6 7 8 9 10 11


See also: TracQuery, TracTickets, TracReports

Last modified 3 years ago Last modified on Nov 26, 2022, 2:16:40 PM
Note: See TracWiki for help on using the wiki.